TTP-244 Plus Bar Code
Printer Service Manual
4.8 Ribbon Sensor (Receiver) Replacement
1. Follow the instructions in Section 4.2 to take out the mechanism.
2. Open the print carriage.
3. Remove the screws, springs and spring bushing on both sides of the mechanism.
Note: The left side spring and the right side spring are different in shape. The right
side spring has a straight end, when the left side spring has an end that is
curved 90 degrees.
4. The main mechanism is divided into upper mechanism and lower mechanism.
5. And ribbon sensor (receiver) is located in the upper mechanism. Remove the screws on the
ribbon sensor cover.